Simulations of the three BGA fanouts I've been comparing are done. I'll probably...

@azonenberg@ioc.exchange

Simulations of the three BGA fanouts I've been comparing are done.

I'll probably wait until I have a few other things finished to close it out and film the video I was panning.

But in short... insertion loss behavior of the two routings is very close, within half a dB or so almost the entire path and criscrossing a few times. The "good" is actually about a dB worse at 35 GHz but this is beyond the 3rd harmonic of the data rate so I don't really care.

Time domain return loss behavior is where the difference shows - the version with no cutouts is atrocious (who would have guessed, lol) and the old fanout has much worse performance in the BGA escape area (left side of the TDR trace, which is from the BGA's perspective with T=100ns at the launch).