INVALID SPECIFIED SYSTEM ACTUATION Palisades (MI), 09/06/2026 "At 0254 EDT, on S...

@whoopsie@tds.xyz

INVALID SPECIFIED SYSTEM ACTUATION
Palisades (MI), 09/06/2026
"At 0254 EDT, on September 6, 2026, operations received a containment isolation signal from the 'right' train fuel handling area radiation monitor (RIA-2317). At 0256 EDT, operations entered AOP-31, Spurious Containment Isolation, and performed the required abnormal operating procedure actions. All 'right' train valves actuated as designed.

"Radiation protection performed surveys of the general area of the…